Datasheets
Featured Application Notes
More Application Notes
All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/packaging/leadfree.
A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/quality/green.
National's certificate of product compliance is located at RoHS Status.
All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/packaging/leadfree.
A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/quality/green.
National's certificate of product compliance is located at RoHS Status.
Reliability Metrics
| Part Number |
Process |
EFR Reject |
EFR Sample Size |
PPM |
LTA Rejects |
LTA Device Hours |
FITS |
MTTF (Hours) |
|
LM5101CMA | ABCD150XV2 | 0 | 3601 | 0 | 0 | 1155496 | 4 | 327875145
|
|
LM5101CMAX | ABCD150XV2 | 0 | 3601 | 0 | 0 | 1155496 | 4 | 327875145
|
|
LM5101CMY | ABCD150XV2 | 0 | 3601 | 0 | 0 | 1155496 | 4 | 327875145
|
|
LM5101CMYE | ABCD150XV2 | 0 | 3601 | 0 | 0 | 1155496 | 4 | 327875145
|
|
LM5101CMYX | ABCD150XV2 | 0 | 3601 | 0 | 0 | 1155496 | 4 | 327875145
|
|
LM5101CSD | ABCD150XV2 | 0 | 3601 | 0 | 0 | 1155496 | 4 | 327875145
|
|
LM5101CSDX | ABCD150XV2 | 0 | 3601 | 0 | 0 | 1155496 | 4 | 327875145
|
Note: The Early Failure Rates (EFR) were calculated as point estimate PPM based on rejects and sample size for EFR.
The Long Term Failure Rates were calculated
at 60% confidence using the Arrhenius equation at 0.7eV activation energy and derating the assumed stress
temperature of 150°C to an application temperature of 55°C.
For more information on Reliability Metrics, please click
here.
All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/packaging/leadfree.
A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/quality/green.
National's certificate of product compliance is located at RoHS Status.